Yaskawa Solectria 60kW 480VAC 3-Phase String Inverter
Yaskawa Solectria 60kW 480VAC 3-Phase String Inverter
SKU:PVI-60TL-480
MUST ORDER WIRING BOX & Shade cover accessory required for installation of 75° or less
Couldn't load pickup availability
Share

Characteristics
+Rated Power Output [W]: 60000
Characteristics
Get pay-when-paid terms up to 120 days plus a 0.5% rebate with Billd
MUST ORDER WIRING BOX
*Shade cover accessory required for installation of 75° or less
Email info@renvu.com to select a wiring box for your order:
- PVI-50-60TL-BX-S20: Wiring Box for PVI 50/60TL Transformerless Inverter, 15 Fused Inputs (5 per Zone), 20A fuses included [MUST ORDER INVERTER TOP BOX]
- PVI-50-60TL-WB-APS: Wiring Box for PVI 50/60TL Transformerless Inverter, 15 Fused Inputs (5 per Zone), 20A fuses included [MUST ORDER INVERTER TOP BOX], includes PLC transmitter and bleed-down circuit for Module-Level Rapid Shutdown with APsmart receivers (RSD-APS, RSD-APS-Q, RSD-APS-D20).
- PVI-50-60TL-WB-NEP: Wiring Box for PVI 50/60TL Transformerless Inverter, 15 Fused Inputs (5 per Zone), 20A fuses included [MUST ORDER INVERTER TOP BOX], includes PLC transmitter and bleed-down circuit for Module-Level Rapid Shutdown with NEP PVG-2 receivers.
- PVI-50-60TL-WB-TGO: Wiring Box for PVI 50/60TL Transformerless Inverter, 15 Fused Inputs (5 per Zone), 20A fuses included [MUST ORDER INVERTER TOP BOX], includes PLC transmitter and bleed-down circuit for Module-Level Rapid Shutdown with Tigo TS4- F, TS4-A-F (ver 6.7+) and TS4-A-2F.
- PVI-36-50-60TL-WB-S: Wiring Box for PVI 36(V2)/50/60TL Transformerless Inverter, 15 Fused Inputs (5 per Zone), 20A fuses included [MUST ORDER INVERTER TOP BOX].
- PVI-36-50-60TL-WB-AP: Wiring Box for PVI 36(V2)/50/60TL Transformerless Inverter, 15 Fused Inputs (5 per Zone), 20A fuses included [MUST ORDER INVERTER TOP BOX], includes PLC transmitter and bleed-down circuit for Module-Level Rapid Shutdown with APsmart receivers (RSD-APS, RSD-APS-Q, RSD-APS-D20).
- PVI-36-50-60TL-WB-NP: Wiring Box for PVI 36(V2)/50/60TL Transformerless Inverter, 15 Fused Inputs (5 per Zone), 20A fuses included [MUST ORDER INVERTER TOP BOX], includes PLC transmitter and bleed-down circuit for Module-Level Rapid Shutdown with NEP PVG-2 receivers.
- PVI-36-50-60TL-WB-TG: Wiring Box for PVI 36(V2)/50/60TL Transformerless Inverter, 15 Fused Inputs (5 per Zone), 20A fuses included [MUST ORDER INVERTER TOP BOX], includes PLC transmitter and bleed-down circuit for Module-Level Rapid Shutdown with Tigo TS4- F, TS4-A-F (ver 6.7+) and TS4-A-2F.
- PVI-50-60TL-BX-R: Wiring Box for PVI 50/60TL Transformerless Inverter, 15 Fused Inputs (5 per Zone), 15A fuses included [MUST ORDER INVERTER TOP BOX], includes PLC transmitter and bleed-down circuit for Module-Level Rapid Shutdown with Tigo TS4- F, TS4-A-2F and TS4-A-F (ver 6.7+).
- PVI-50-60TL-BX-H: Wiring Box for PVI 50/60TL Transformerless Inverter, 15 Fused Inputs (5 per Zone), 15A fuses included, with Amphenol H4 PV Connectors [MUST ORDER INVERTER TOP BOX]
Yaskawa Solectria Solar’s PVI 60TL-480 is a transformerless 3-phase inverter, ideal for rooftops, carports and ground-mount PV systems.
The PVI-60TL-480 comes standard with AC and DC disconnects, three MPPTs, and a wiring box with 15 fuse positions.
For rooftop PV systems, both Module-Level Rapid shutdown (MLRSD) wirebox models provide PV Rapid Shutdown System (PVRSS) compliance and include a built-in SunSpec compliant powerline communication transmitter.
One wirebox model is Tigo Enhanced for rapid shutdown and the other two wirebox models are compatible with APsmart or NEP rapid shutdown devices. MUST ORDER WIRING BOX; email info@renvu.com to select.
Yaskawa Solectria Solar’s family of PVI-50/60TL-480 inverters, including standard wireboxes and the rapid shutdown ready wirebox models, provides flexibility and convenience unmatched in the industry.